VTechWorks staff will be away for the winter holidays starting Tuesday, December 24, 2024, through Wednesday, January 1, 2025, and will not be replying to requests during this time. Thank you for your patience, and happy holidays!
 

Monitoring the SNS basement neutron background with the MARS detector

dc.contributor.authorAkimov, D.en
dc.contributor.authorAn, P.en
dc.contributor.authorAwe, C.en
dc.contributor.authorBarbeau, P. S.en
dc.contributor.authorBecker, B.en
dc.contributor.authorBelov, V.en
dc.contributor.authorBernardi, I.en
dc.contributor.authorBlackston, M. A.en
dc.contributor.authorBock, C.en
dc.contributor.authorBolozdynya, A.en
dc.contributor.authorBrowning, J.en
dc.contributor.authorCabrera-Palmer, B.en
dc.contributor.authorChernyak, D.en
dc.contributor.authorConley, E.en
dc.contributor.authorDaughhetee, J.en
dc.contributor.authorDetwiler, J.en
dc.contributor.authorDing, K.en
dc.contributor.authorDurand, M. R.en
dc.contributor.authorEfremenko, Y.en
dc.contributor.authorElliott, S. R.en
dc.contributor.authorFabris, L.en
dc.contributor.authorFebbraro, M.en
dc.contributor.authorRosso, A. Galloen
dc.contributor.authorGalindo-Uribarri, A.en
dc.contributor.authorGreen, M. P.en
dc.contributor.authorHeath, M. R.en
dc.contributor.authorHedges, S.en
dc.contributor.authorHoang, D.en
dc.contributor.authorHughes, M.en
dc.contributor.authorJohnson, T.en
dc.contributor.authorKhromov, A.en
dc.contributor.authorKonovalov, A.en
dc.contributor.authorKozlova, E.en
dc.contributor.authorKumpan, A.en
dc.contributor.authorLi, L.en
dc.contributor.authorLink, Jonathan M.en
dc.contributor.authorLiu, J.en
dc.contributor.authorMann, K.en
dc.contributor.authorMarkoff, D. M.en
dc.contributor.authorMastroberti, J.en
dc.contributor.authorMueller, P. E.en
dc.contributor.authorNewby, J.en
dc.contributor.authorParno, D. S.en
dc.contributor.authorPenttila, S.en
dc.contributor.authorPershey, D.en
dc.contributor.authorRapp, R.en
dc.contributor.authorRay, H.en
dc.contributor.authorRaybern, J.en
dc.contributor.authorRazuvaeva, O.en
dc.contributor.authorReyna, D.en
dc.contributor.authorRich, G. C.en
dc.contributor.authorRoss, J.en
dc.contributor.authorRudik, D.en
dc.contributor.authorRunge, J.en
dc.contributor.authorSalvat, D. J.en
dc.contributor.authorSalyapongse, A. M.en
dc.contributor.authorScholberg, K.en
dc.contributor.authorShakirov, A.en
dc.contributor.authorSimakov, G.en
dc.contributor.authorSinev, G.en
dc.contributor.authorSnow, W. M.en
dc.contributor.authorSosnovstsev, V.en
dc.contributor.authorSuh, B.en
dc.contributor.authorTayloe, R.en
dc.contributor.authorTellez-Giron-Flores, K.en
dc.contributor.authorTolstukhin, I.en
dc.contributor.authorUjah, E.en
dc.contributor.authorVanderwerp, J.en
dc.contributor.authorVarner, R. L.en
dc.contributor.authorVirtue, C. J.en
dc.contributor.authorVisser, G.en
dc.contributor.authorWongjirad, T.en
dc.contributor.authorYen, Y. -R.en
dc.contributor.authorYoo, J.en
dc.contributor.authorYu, C. -H.en
dc.contributor.authorZettlemoyer, J.en
dc.contributor.authorJohnson, B. A.en
dc.date.accessioned2024-01-22T16:06:13Zen
dc.date.available2024-01-22T16:06:13Zen
dc.date.issued2022-03-22en
dc.description.abstractWe present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m2/MWh for neutron energies above ∼3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.en
dc.description.versionPublished versionen
dc.format.extent25 page(s)en
dc.format.mimetypeapplication/pdfen
dc.identifierARTN P03021 (Article number)en
dc.identifier.doihttps://doi.org/10.1088/1748-0221/17/03/P03021en
dc.identifier.eissn1748-0221en
dc.identifier.issn1748-0221en
dc.identifier.issue3en
dc.identifier.orcidLink, Jonathan [0000-0002-1514-0650]en
dc.identifier.urihttps://hdl.handle.net/10919/117526en
dc.identifier.volume17en
dc.language.isoenen
dc.publisherIOPen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectNeutron detectors (cold, thermal, fast neutrons)en
dc.subjectNeutrino detectorsen
dc.titleMonitoring the SNS basement neutron background with the MARS detectoren
dc.title.serialJournal of Instrumentationen
dc.typeArticle - Refereeden
dc.type.dcmitypeTexten
dc.type.otherArticleen
dc.type.otherJournalen
pubs.organisational-group/Virginia Techen
pubs.organisational-group/Virginia Tech/Scienceen
pubs.organisational-group/Virginia Tech/Science/Physicsen
pubs.organisational-group/Virginia Tech/All T&R Facultyen
pubs.organisational-group/Virginia Tech/Science/COS T&R Facultyen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Akimov_2022_J._Inst._17_P03021.pdf
Size:
8.06 MB
Format:
Adobe Portable Document Format
Description:
Published version
License bundle
Now showing 1 - 1 of 1
Name:
license.txt
Size:
1.5 KB
Format:
Plain Text
Description: