Chemosensory Evaluation of Training and Oxidative Stress in Long Distance Runners

dc.contributor.authorWhysong, Christanen
dc.contributor.committeechairMallikarjunan, Parameswaranen
dc.contributor.committeememberLo, Jennyen
dc.contributor.committeememberGrisso, Robert D.en
dc.contributor.committeememberBrolinson, P. Gunnaren
dc.contributor.departmentBiological Systems Engineeringen
dc.date.accessioned2014-03-14T20:47:46Zen
dc.date.adate2009-11-23en
dc.date.available2014-03-14T20:47:46Zen
dc.date.issued2009-10-28en
dc.date.rdate2013-05-20en
dc.date.sdate2009-11-11en
dc.description.abstractAthletic performance is improved by increasing training loads but it is difficult to determine an athlete's response to a training load and the amount of stress incurred. This makes athletes susceptible to overtraining, leading to decreased performance levels, due to physical exhaustion and oxidative stress. Past studies have observed a myriad of biomarkers without conclusively identifying a clinically specific marker for overtraining due to oxidative stress. These methods require invasive testing and lengthy result times, making real-time adjustments of training programs to prevent overtraining difficult. The use of an electronic nose (enose) as a non-invasive evaluation tool will provide immediate feedback on training stress, allowing for real-time training adjustments for performance optimization. Two long distance runners (one male and one female) completed a pilot study. Both performed a short run and the female performed a long run. Blood samples were collected from each athlete before and after each run and analyzed for catalase and GPx activity. Breath samples were also collected before and after each run and analyzed by an enose. Multivariate analyses of combined blood data yielded better results than individual analyses. Although data was limited for this pilot study, canonical discriminant analyses (CDA) showed separation between before and after run and between short and long run breath samples. Cross validations also found up to a 77.8 percent prediction accuracy for the enose. Results indicate an enose is feasible for detecting changes in the breath occurring after physically demanding exercise perhaps due to oxidative stress incurred during the exercise.en
dc.description.degreeMaster of Scienceen
dc.identifier.otheretd-11112009-034424en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-11112009-034424/en
dc.identifier.urihttp://hdl.handle.net/10919/35665en
dc.publisherVirginia Techen
dc.relation.haspartWhysong_CY_T_2009.pdfen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectelectronic noseen
dc.subjectovertrainingen
dc.subjectlong distance runnersen
dc.subjectoxidative stressen
dc.subjectnoninvasive testingen
dc.titleChemosensory Evaluation of Training and Oxidative Stress in Long Distance Runnersen
dc.typeThesisen
thesis.degree.disciplineBiological Systems Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Whysong_CY_T_2009.pdf
Size:
2.88 MB
Format:
Adobe Portable Document Format

Collections