Determination of Crispness in Breaded Fried Chicken Nuggets Using Ultrasonic Technique

dc.contributor.authorAntonova, Irinaen
dc.contributor.committeechairMallikarjunan, Parameswaran Kumaren
dc.contributor.committeememberHaugh, C. Geneen
dc.contributor.committeememberDuke, John C. Jr.en
dc.contributor.committeememberDuncan, Susan E.en
dc.contributor.departmentBiological Systems Engineeringen
dc.date.accessioned2014-03-14T20:50:50Zen
dc.date.adate2001-12-28en
dc.date.available2014-03-14T20:50:50Zen
dc.date.issued2001-12-18en
dc.date.rdate2004-12-28en
dc.date.sdate2001-12-27en
dc.description.abstractCrispness is one of the most important and desirable textural characteristics that signify freshness and high quality in breaded fried foods. Though many approaches to instrumental measurement of crispness have been made, the best measurements are still inconclusive. There is no reliable method available that can accurately measure and quantify crispness in breaded fried foods. In this study, the mechanical and ultrasonic techniques were used to determine crispness in breaded fried chicken nuggets under different storage conditions. The mechanical measurements have been made, using an Instron universal testing machine. An ultrasonic non-destructive evaluation system was used to measure ultrasonic properties of breaded friend chicken nuggets. A pair of dry-coupling 250-kHz ultrasonic transducers was used to perform the ultrasonic transmission through the breaded fried chicken nugget. The equipment set up was in the through-transmission mode because breaded fried chicken nugget is highly attenuative material. A sensory panel of eight members was trained to evaluate crispness in breaded fried foods. Panelists rated crispness on a nine-point category scale (1 = not crisp/soggy, 9 = very crisp). Sensory crispness values for breaded fried foods under different storage conditions were obtained. Ultrasonic velocity, transmission loss, peak frequencies and its energies, peak force and total energy were determined for each tested product. Correlation between sensory crispness and instrumental parameters suggests that the ultrasonic method can be used to evaluate crispness. The ultrasonic velocity had high correlation with sensory crispness (R2 = 0.83). This indicates that sensory crispness could be reasonably well predicted by the ultrasonic velocity.en
dc.description.degreeMaster of Scienceen
dc.identifier.otheretd-12272001-172605en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-12272001-172605/en
dc.identifier.urihttp://hdl.handle.net/10919/36456en
dc.publisherVirginia Techen
dc.relation.haspartThesis.pdfen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectBreaded Fried Foodsen
dc.subjectSensoryen
dc.subjectCrispnessen
dc.subjectChicken Nuggetsen
dc.subjectUltrasonicsen
dc.titleDetermination of Crispness in Breaded Fried Chicken Nuggets Using Ultrasonic Techniqueen
dc.typeThesisen
thesis.degree.disciplineBiological Systems Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Thesis.pdf
Size:
431.7 KB
Format:
Adobe Portable Document Format

Collections