Comparison of two hydrological models on a Virginia Piedmont watershed

dc.contributor.authorFu, Youtongen
dc.contributor.committeechairShanholtz, Vernon O.en
dc.contributor.committeememberMostaghimi, Saieden
dc.contributor.committeememberLoganathan, G. V.en
dc.contributor.committeememberPerumpral, John V.en
dc.contributor.departmentAgricultural Engineeringen
dc.date.accessioned2014-03-14T21:35:37Zen
dc.date.adate2010-05-04en
dc.date.available2014-03-14T21:35:37Zen
dc.date.issued1994-12-05en
dc.date.rdate2010-05-04en
dc.date.sdate2010-05-04en
dc.description.abstractKINEROS and PSRM-QUAL:J two distributed parameter event-based hydrologic models, were applied to Foster Creek Watershed, Louisa County, Virginia. The simulations of the two models were conducted using published data and a ten year database from the Foster Creek Watershed, Louisa County, Virginia. Data management and analysis was supported through the use of PC-VirGIS, a DOS based GIS package developed by the Information Support Systems Laboratory, Virginia Tech. The performance of the two models were based on the criteria established to compare the simulated and recorded peak discharge rates , total runoff volumes and time to peak. Goodness of fit criteria were based on graphic comparison relative error, model efficiency, linear regression, hypothesis testing and variance. Based on these measurements, the simulated results by both models were acceptable. KINEROS generally made better predictions of peak discharge rate and time to peak. Hydrograph shapes also generally matched the recorded sequence more closely. PSRM-QUAL simulated the total runoff volume slightly better than KINEROS. The sensitivity of KINER OS and PSRM-QUAL to the model input parameters was evaluated. For KINEROS, peak discharge rate and runoff volume were very sensitive to changes in rainfall amount, saturated hydraulic conductivity and effective capillary drive. For PSRM-QUAL, peak discharge rate and total runoff volume were very sensitive to changes in SCS CN, initial abstraction coefficient and rainfall amount.en
dc.description.degreeMaster of Scienceen
dc.format.extentxv, 236 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-05042010-020347en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-05042010-020347/en
dc.identifier.urihttp://hdl.handle.net/10919/42490en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1994.F8.pdfen
dc.relation.isformatofOCLC# 32305665en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1994.F8en
dc.subject.lcshHydrologic modelsen
dc.subject.lcshFoster Creek Watershed (Va) -- Mathematical modelsen
dc.titleComparison of two hydrological models on a Virginia Piedmont watersheden
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineAgricultural Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V855_1994.F8.pdf
Size:
6.88 MB
Format:
Adobe Portable Document Format

Collections