Comparison of laboratory protocols for yielding improved estimates of hearing protection in field performance for use in standards development

dc.contributor.authorRichards, Michael Llewellynen
dc.contributor.departmentIndustrial and Systems Engineeringen
dc.date.accessioned2014-03-14T21:32:04Zen
dc.date.adate2010-03-17en
dc.date.available2014-03-14T21:32:04Zen
dc.date.issued1991en
dc.date.rdate2010-03-17en
dc.date.sdate2010-03-17en
dc.description.abstractFederal law requires hearing protection device (HPD) manufacturers to provide attenuation ratings for use in estimating workers’ protection levels. These ratings, which are laboratory obtained, typically overestimate the actual protection levels achieved in the workplace. This research investigated laboratory protocols for yielding improved estimates of HPD in-field performance. Two experiments were conducted. The first was a pilot study developed by an American National Standards Institute (ANSI) working group. In this experiment, two types of earplugs were tested, a user-molded, malleable foam plug and a pre-molded, multi-sized rubber plug. Attenuation data (obtained using a psychoacoustical real-ear-attenuation-at-threshold measurement procedure) were collected across 10 subjects who entered the study as novice HPD users but were considered experienced HPD users in the latter half of the study. Four testing protocols involving two levels of HPDs, two levels of instruction-insertion techniques, and two levels of user experience were investigated. The same 10 subjects participated in all treatment conditions of the experiment. The second experiment involved similar protocols as the first; however, only one plug type was tested (the pre-molded, multi-sized rubber plug). Four testing protocols involving two levels of instruction-insertion techniques, two levels of user experience, and two levels of auditory feedback [fitting noise] were investigated. Forty subjects participated; each subject was tested in two treatment conditions. The attenuation results of each experiment were analyzed by statistical techniques. Statistical comparisons of results were made between the two experiments as well as between the experiments and selected field data. The major finding of the research was that fitting noise did not help subjects achieve higher attenuation [better protection] when consciously used for that purpose. Other findings indicated that novice subjects using only HPD manufacturer's instructions achieved attenuation that more closely represented the field attenuation than subjects tested under other conditions. However, the results were plug specific, in that no laboratory protocols yielded attenuation similar to the field data for the foam plug.en
dc.description.degreeMaster of Scienceen
dc.format.extentxvi, 291 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-03172010-020615en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-03172010-020615/en
dc.identifier.urihttp://hdl.handle.net/10919/41713en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1991.R534.pdfen
dc.relation.isformatofOCLC# 24956663en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1991.R534en
dc.subject.lcshHearing levelsen
dc.subject.lcshHearingen
dc.titleComparison of laboratory protocols for yielding improved estimates of hearing protection in field performance for use in standards developmenten
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineIndustrial and Systems Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen