Evaluation of the Bird Mark 8 respirator with J circuit for neonatal application

dc.contributor.authorYeeda, Daviden
dc.contributor.departmentIndustrial Engineeringen
dc.date.accessioned2024-05-08T00:08:00Zen
dc.date.available2024-05-08T00:08:00Zen
dc.date.issued1967en
dc.description.abstractThis study presents an evaluation of the Bird Mark 8 Respirator with J Circuit in neonatal application. The system was studied with special attention to the desirability of its possible application in the treatment of a respiratory ailment of newborn infants called hyaline membrane disease. The project involved the determination of response time of the respirator and blood gas characteristics in rabbits after ventilation by the equipment. Rabbits were used in the experiment because their respiratory behavior resembles that of new-born infants with respiratory distress. The respiration of rabbits was assisted with air supplied to the respirator at 50 p.s.i. Average response times (minimum of 114 milliseconds, for the case of the rabbit tripping the respirator, with 1 centimeter of water negative pressure in the delivery line), were determined to be in excess of the 20-30 milliseconds maximum limit that may be tolerated by the infant in the treatment of this disease. Blood gas characteristics of the rabbits ventilated for 2 hours with the respirator showed significant increases in the partial pressure of carbon dioxide and significant decreases in the partial pressure of oxygen and pH levels, as compared with the normal blood gas characteristics. These changes are considered undesirable. From this study it is believed that the respirator does not provide the adequate assistance to respiration required for the treatment of infants afflicted with respiratory distress.en
dc.description.degreeM. S.en
dc.format.extentiii, 132 leavesen
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://hdl.handle.net/10919/118876en
dc.language.isoenen
dc.publisherVirginia Polytechnic Instituteen
dc.relation.isformatofOCLC# 38265811en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1967.Y39en
dc.titleEvaluation of the Bird Mark 8 respirator with J circuit for neonatal applicationen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineIndustrial Engineeringen
thesis.degree.grantorVirginia Polytechnic Instituteen
thesis.degree.levelmastersen
thesis.degree.nameM. S.en