Simultaneous measurement of strain and temperature using liquid core optical fiber sensors

dc.contributor.authorDe Vries, Marten J.en
dc.contributor.committeechairClaus, Richard O.en
dc.contributor.committeememberMurphy, Kent A.en
dc.contributor.committeememberPoon, Ting-Chungen
dc.contributor.departmentElectrical Engineeringen
dc.date.accessioned2014-03-14T21:30:44Zen
dc.date.adate2009-03-04en
dc.date.available2014-03-14T21:30:44Zen
dc.date.issued1993-01-15en
dc.date.rdate2009-03-04en
dc.date.sdate2009-03-04en
dc.description.abstractA liquid core fiber sensor can be used to sense both strain and temperature simultaneously. This liquid core fiber sensor is comprised of a hollow core optical fiber filled with a liquid of a known index of refraction which is slightly higher than that of the silica tube which acts as the cladding. The refractive index fluid is chosen such that the variation of its refractive index with strain and temperature is well defined and linear in the desired range of operation. The core of the sensing fiber contains a fluid which has a thermo-optic coefficient much larger in magnitude (-4.0x10⁻⁴/°C) than that of the silica cladding. This causes the fiber to be more sensitive to temperature changes than all-silica fibers. Both transmitted optical signal intensity and time-of-flight depend strongly on applied strain and temperature. Furthermore, the relative difference between the core and cladding refractive indices changes as a function of both parameters due to the inherently different material types used in the fiber construction. This results in critical strain and temperature regimes within which the refractive index difference is very small, and sensitivity is optimized. Testing of prototype sensors demonstrates these characteristics. A 0.47 m long liquid core fiber containing a liquid with a room temperature refractive index of 1.492 was analyzed. Both time- and intensity-domain behaviors around the device's critical temperature (95°C) confirm theoretical expectations. Simultaneous strain and temperature measurements were performed between 95 °C and 105 °C. Methods for multiplexing liquid core fibers for increasing the range of temperatures that can be monitored were also investigated as well as using those liquid core fibers for cooling purposes.en
dc.description.degreeMaster of Scienceen
dc.format.extentvii, 48 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-03042009-040438en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-03042009-040438/en
dc.identifier.urihttp://hdl.handle.net/10919/41392en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1993.V754.pdfen
dc.relation.isformatofOCLC# 27843857en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1993.V754en
dc.subject.lcshOptical detectorsen
dc.subject.lcshOptical fibersen
dc.subject.lcshStrains and stresses -- Measurementen
dc.subject.lcshTemperature measuring instrumentsen
dc.titleSimultaneous measurement of strain and temperature using liquid core optical fiber sensorsen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineElectrical Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V855_1993.V754.pdf
Size:
2.04 MB
Format:
Adobe Portable Document Format
Description:

Collections