dc.description.abstractIn this study, connection classification system is developed on the basis of previous classifications. Further, flexible connections are modeled by matrix displacement method. The effect of flexible connections are studied on gable frames. Firstly, flush end-plate connections with single row of bolts at the tension flange, are classified. The classification system was developed in this study. End plate connections whose moment-rotation curves are known arc classified on the basis of moments as FR (fully restrained) and PR (partially restrained) connections. Further, the connections are also classified by entering a plot with coordinates - Ratio of Moment at the connection and plastic moment and ratio of corresponding rotation and rotation at plastic moment. Depending on the location the connection can be classified. Secondly, for connections, the rotational stiffness is determined from the moment rotation curves and used in the computer code to implement flexible connections. The effect is studied on gable frames. For the loading and frame used there is not much variation in moments at the flexible joints due to connection flexibility and hence flush end plate connections can be used in gable frames effectivelyen
dc.description.degreeMaster of Scienceen
dc.format.extentx, 103 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-03122009-040618en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-03122009-040618/en
dc.identifier.urihttp://hdl.handle.net/10919/41460en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1990.B363.pdfen
dc.relation.isformatofOCLC# 21727424en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1990.B363en
dc.subject.lcshBuilding, Iron and steelen
dc.subject.lcshPlates (Engineering)en
dc.titleClassification of end plate connections with application to gable framesen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen