VTechWorks staff will be away for the Thanksgiving holiday beginning at noon on Wednesday, November 27, through Friday, November 29. We will resume normal operations on Monday, December 2. Thank you for your patience.
 

Kinematics of the wrist during a keying task: the effects of workstation design and work pace

dc.contributor.authorBowman, Darrell Scotten
dc.contributor.committeechairKroemer, Karl H. E.en
dc.contributor.committeememberWilliges, Robert C.en
dc.contributor.committeememberKleiner, Brian M.en
dc.contributor.departmentIndustrial and Systems Engineeringen
dc.date.accessioned2014-03-14T21:29:13Zen
dc.date.adate2009-02-13en
dc.date.available2014-03-14T21:29:13Zen
dc.date.issued1996-06-17en
dc.date.rdate2009-02-13en
dc.date.sdate2009-02-13en
dc.description.abstractSince the advent of keyboards into the workplace, workers began to experience disorders of the tendons and nerves of the upper extremities, referred to as cumulative trauma disorders, due to the repeated exertions and excessive movements. One of the major research voids in the study of occupational injuries to the wrist is the lack of understanding of the kinematic nature of the wrist during keying tasks. Changes in wrist position were measured on 9 males and 9 females while keying, in the flexion/extension and radial/ ulnar planes. This information was then used to determine the wrist dynamic characteristics, then wrist accelerations were derived. The effects of Gender, Keyboard Height (5 cm below sitting elbow height, at sitting elbow height, 5 cm above elbow height), Keyboard Angle (-30 degrees from horizontal, horizontal, +30 from horizontal), and Keying Rate( 110 and 90 percent of the individual's average typing rate) on wrist accelerations were scrutinized. The results of this study indicated that, throughout the keying task, there were a significant changes in wrist position (p < 0.05). Keyboard Height was the only significant variable (p < 0.05) on the magnitude of mean peak wrist acceleration. The lowest magnitude of wrist acceleration occurred when the keyboard was positioned 5 cm below the user's sitting elbow height From these findings it appears that the methods used were effective in determining the kinematic nature of the wrist during a keying task. Specifically, the technique employed is adequate for measuring the accelerations of the wrist, but future research is needed to more accurately define the factors that influence the magnitude of wrist accelerations.en
dc.description.degreeMaster of Scienceen
dc.format.extentx, 134 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-02132009-171758en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-02132009-171758/en
dc.identifier.urihttp://hdl.handle.net/10919/41059en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1996.B696.pdfen
dc.relation.isformatofOCLC# 35303185en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectmotionen
dc.subjectkeyingen
dc.subjectcumulative trauma disordersen
dc.subjectwristen
dc.subject.lccLD5655.V855 1996.B696en
dc.titleKinematics of the wrist during a keying task: the effects of workstation design and work paceen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineIndustrial and Systems Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V855_1996.B696.pdf
Size:
106.91 MB
Format:
Adobe Portable Document Format

Collections