Evaluation of the base test method for determining the strength of standing seam roof systems under gravity loadings

dc.contributor.authorBrooks, Steven D.en
dc.contributor.committeechairMurray, Thomas M.en
dc.contributor.committeememberEasterling, William Samuelen
dc.contributor.committeememberBarker, Richard M.en
dc.contributor.departmentCivil Engineeringen
dc.date.accessioned2014-03-14T21:50:27Zen
dc.date.adate2012-11-21en
dc.date.available2014-03-14T21:50:27Zen
dc.date.issued1989-12-05en
dc.date.rdate2012-11-21en
dc.date.sdate2012-11-21en
dc.description.abstractThe base tGSt method has been proposed by Carballo, Holzer and Murray [5] as a means of determining the strength of standing seam roof systems under gravity loading. The objective of this thesis is to evaluate the accuracy of the base test method. To do this, eleven sets of tests were performed at Virginia Polytechnic Institute & State University (VPl&SU). Each test set consisted of a single span base test from which a failure load was predicted for the corresponding three span confirming test. Results of two test sets recorded in Reference [5] were also used to evaluate the method. A secondary objective of this thesis is to comment on the effects that system components (purlin orientation, clip type, bracing configuration, panel type, insulation and purlin type) have on the strength of the system. Results from proprietary tests conducted at VPI & SU were used in conjunction with the results from this research to accomplish the secondary objective.en
dc.description.degreeMaster of Scienceen
dc.format.extentviii, 58 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-11212012-040208en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-11212012-040208/en
dc.identifier.urihttp://hdl.handle.net/10919/45958en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1989.B764.pdfen
dc.relation.isformatofOCLC# 21349635en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1989.B764en
dc.subject.lcshCommercial buildings -- Roofs -- Design and construction -- Researchen
dc.subject.lcshRoofs -- Design and construction -- Researchen
dc.titleEvaluation of the base test method for determining the strength of standing seam roof systems under gravity loadingsen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen