Step Misaligned and Film Cooled Nozzle Guide Vanes at Transonic Conditions: Heat Transfer
Files
TR Number
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This study describes a detailed investigation on the effects that upstream step misalignment and upstream purge film cooling have on the endwall heat transfer for nozzle guide vanes in a land based power generation gas turbine at transonic conditions. Endwall Nusselt Number and adiabatic film cooling effectiveness distributions were experimentally calculated and compared with qualitative data gathered via oil paint flow visualization which also depicts endwall flow physics. Tests were conducted in a transonic linear cascade blowdown facility. Data were gathered at an exit Mach number of 0.85 with a freestream turbulence intensity of 16% at a Re = 1.5 x 106 based on axial chord. Varied upstream purge blowing ratios and a no blowing case were tested for 3 different upstream step geometries, one of which was the baseline (no step). The other two geometries are a backward step geometry and a forward step geometry, which comprised of a span-wise upstream step of +4.86% span and -4.86% span respectively.
Experimentation shows that the addition of upstream purge film cooling increases the Nusselt Number at injection upwards of 50% but lowers it in the throat of the passage by approximately 20%. The addition of a backward facing step induces more turbulent mixing between the coolant and mainstream flows, thus reducing film effectiveness coverage and increasing Nusselt number by nearly 40% in the passage throat. In contrast, the presence of a forward step creates a more stable boundary layer for the coolant flow, thus aiding to help keep the film attached to the endwall at higher blowing ratios. Increasing the blowing ratio increases film cooling effectiveness and endwall coverage up to a certain point, beyond which, the high momentum of the coolant results in poor cooling performance due to jet liftoff. Near endwall streamlines without purge cooling generated by Li et al. [1] for the same geometries were compared to the experimental data. It was shown that even with the addition of upstream purge cooling, the near endwall streamlines as they moved downstream matched strikingly well with the experimental data. This discovery indicates that while the coolant flow will likely affect the flow streamlines three dimensionally, they are minimally effected by the coolant flow near the endwall as the flow moves downstream.