Methods for Evaluating Aquifer-System Parameters from a Cumulative Compaction Record

dc.contributor.authorVanhaitsma, Amanda Joyen
dc.contributor.committeechairBurbey, Thomas J.en
dc.contributor.committeememberSchreiber, Madeline E.en
dc.contributor.committeememberDu, Pangen
dc.contributor.departmentGeosciencesen
dc.date.accessioned2016-08-13T08:00:13Zen
dc.date.available2016-08-13T08:00:13Zen
dc.date.issued2016-08-12en
dc.description.abstractAlthough many efforts and strategies have been implemented to reduce over-pumping of aquifer-systems, land subsidence is still a serious issue worldwide. Accurate aquifer characterization is critical to understand the response of an aquifer-system to prolonged pumping but is often difficult and expensive to conduct. The purpose of this thesis is to determine the validity of estimating aquifer-system parameters from a single cumulative compaction record and corresponding nested water-level data deconvolved into temporal components. Over a decade of compaction and water-level data were collected from an extensometer and multi-level piezometer at the Lorenzi site in Las Vegas Valley and when graphed yearly, seasonal, and daily signals are observed. Each temporal signal reflects different characteristics of the aquifer-system, including the distinction between aquifer and aquitard parameters, as the three temporal stresses influence the compaction record uniquely. Maximum cross-correlation was used to determine the hydrodynamic lag between changing water-levels and subsidence within the seasonal signal while principal components analysis was used to statistically verify the presence of the three temporal signals. Assumptions had to be made but nearly all estimated Lorenzi site aquifer-system parameters fell either within the reasonable range or were similar in magnitude to parameter values estimated in previous studies. Unfortunately, principal components analysis was unable to detect the three temporal signals. A cumulative compaction record may be difficult to obtain but analyzing the precision measurements of an extensometer results in precise aquifer-system parameters and as the precision of aquifer-system parameters increase so does the ability to sustainably manage groundwater.en
dc.description.degreeMaster of Scienceen
dc.format.mediumETDen
dc.identifier.othervt_gsexam:8281en
dc.identifier.urihttp://hdl.handle.net/10919/72245en
dc.publisherVirginia Techen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectaquifer-system parametersen
dc.subjectcompactionen
dc.subjectLorenzi siteen
dc.subjectLas Vegasen
dc.subjectsubsidenceen
dc.titleMethods for Evaluating Aquifer-System Parameters from a Cumulative Compaction Recorden
dc.typeThesisen
thesis.degree.disciplineGeosciencesen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Vanhaitsma_AJ_T_2016.pdf
Size:
2.48 MB
Format:
Adobe Portable Document Format

Collections