Development and Validation of a Twelve Bolt Extended Stiffened End-Plate Moment Connection

dc.contributor.authorSzabo, Trevor Alexanderen
dc.contributor.committeechairEatherton, Matthew R.en
dc.contributor.committeememberLeon, Roberto T.en
dc.contributor.committeememberMurray, Thomas M.en
dc.contributor.departmentCivil and Environmental Engineeringen
dc.date.accessioned2017-06-21T08:00:52Zen
dc.date.available2017-06-21T08:00:52Zen
dc.date.issued2017-06-20en
dc.description.abstractThree end-plate moment connection configurations are prequalified for special moment frames for seismic applications in AISC 358-10. The eight bolt extended stiffened connection is the strongest of the three configurations, but it can only develop approximately 30 percent of currently available hot-rolled beam sections. The strength of this configuration is limited by bolt strength. There is a need for a stronger end-plate moment connection, hence the reason for the development and validation of a twelve bolt configuration. Equations were developed for the design procedure using various analytical methods, which included yield line analysis and an effective tee stub model. An experimental program was conducted, which consisted of the full-scale cyclic testing of four end-plate moment connections. The intention of the testing was to develop and validate the design procedure, and prequalify a new twelve bolt configuration. A displacement-controlled loading protocol was applied according to AISC 341-10. The experimental results showed that the model for thick end-plate behavior is conservative by 6.7%, the model for end-plate yielding is conservative by 8.8%, and the model for bolt tension rupture with prying conservatively predicts by 18.5%. The specimens that were designed to form a plastic hinge in the beam fractured in a brittle manner. The deep beam specimen fractured in the first 2% story drift cycle, and the shallow beam specimen fractured in the second 3% story drift cycle. The fracture of the prequalification specimens was determined to have been caused by stiffeners of high yield stress relative to the beam yield stress.en
dc.description.abstractgeneralEnd-plate moment connections are a common way to create a rigid joint between beams and columns. Before using a moment connection in a steel building to resist horizontal earthquake loads, each connection configuration must be tested at full-scale and meet performance criteria prescribed in the applicable building code (in this case, the Seismic Provisions for Structural Steel Buildings published by the American Institute of Steel Construction). Three end-plate moment connection configurations have been previously “prequalified” for high seismic regions, which means that sufficient previous testing has shown adequate performance. The eight bolt end-plate moment connection is the strongest of the three configurations, but it can only develop approximately 30 percent of currently available hot-rolled steel beam sections. The strength of this configuration is limited by bolt strength. There is a need for stronger end-plate moment connections, which motivated the development and validation of a twelve bolt configuration in this thesis. Equations were developed for the design of the twelve-bolt end-plate moment connection including equations to predict when the bolts would fracture and when the end-plate would yield. An experimental program was conducted, which consisted of the full-scale cyclic testing of four end-plate moment connections. The intention of the testing was to validate the design procedure and demonstrate that the connection could withstand significant inelastic rotation. The connection assembly was cycled back and forth according to a displacement protocol prescribed in the Seismic Provisions for Steel Buildings. The experimental results showed that the equations were able to predict bolt rupture within 6.7% of the applied moment at fracture, the equation for end-plate yielding was conservative by 8.8%, and the equation for bolt fracture with prying action was conservative by 18.5%. The specimens that were intended to show the connection could withstand significant inelasticity fractured in an unexpected brittle manner. The deep beam iv specimen fractured in the first 2% story drift cycle, and the shallow beam specimen fractured in the second 3% story drift cycle, neither of which reach the target of 4% story drift. The fractures were determined to have been caused by stiffeners that had too high a yield stress relative to the beam yield stress.en
dc.description.degreeMaster of Scienceen
dc.format.mediumETDen
dc.identifier.othervt_gsexam:11579en
dc.identifier.urihttp://hdl.handle.net/10919/78230en
dc.publisherVirginia Techen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectEnd-Plate Moment Connectionsen
dc.subjectFull-Scale Testingen
dc.subjectMetal Buildingsen
dc.subjectSpecial Moment Resisting Frameen
dc.titleDevelopment and Validation of a Twelve Bolt Extended Stiffened End-Plate Moment Connectionen
dc.typeThesisen
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen