Field and Laboratory Tests of a Proposed Bridge Deck Panel Fabricated from Pultruded Fiber-Reinforced Polymer Components

dc.contributor.authorTemeles, Anthony B.en
dc.contributor.committeecochairLesko, John J.en
dc.contributor.committeecochairCousins, Thomas E.en
dc.contributor.committeememberRoberts-Wollmann, Carin L.en
dc.contributor.departmentCivil Engineeringen
dc.date.accessioned2014-03-14T20:37:27Zen
dc.date.adate2001-05-22en
dc.date.available2014-03-14T20:37:27Zen
dc.date.issued2001-05-14en
dc.date.rdate2002-05-22en
dc.date.sdate2001-05-18en
dc.description.abstractTwo 7" deep FRP deck panels were manufactured and tested in a controlled service environment. The deck panels were 15' by 5' in plan, and were composed of ten 15' long, 6" by 6" by 3/8" standard pultruded FRP tubes. The tubes were sandwiched between two 3/8" thick standard pultruded FRP plates. The material constituents of the FRP were E-glass fibers in a polyester matrix. When subjected to two strength tests, the first deck panel exhibited a safety factor with respect to legal truck loads of greater than 10. The second deck was subjected to AASHTO design loads, and under a simulated HS-25 axle plus impact the deck exhibited a maximum deflection of L/470. Upon completion of the laboratory testing, the second deck was placed in the field for further study. The maximum strain recorded during field testing was approximately 600 microstrain, which is less than 15% of the ultimate tensile strain of the FRP in its weakest direction. After being subjected to approximately 4 million load cycles (assuming 100,000 5-axle truck crossings per month) over a period of 8 months, the deck exhibited no loss in stiffness. In two post-service strength tests, the second deck exhibited a safety factor with respect to legal truck loads of greater than 8 and greater than 13.en
dc.description.degreeMaster of Scienceen
dc.identifier.otheretd-05182001-221501en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-05182001-221501/en
dc.identifier.urihttp://hdl.handle.net/10919/32940en
dc.publisherVirginia Techen
dc.relation.haspartthesis.pdfen
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectpultrusionen
dc.subjectbridge decksen
dc.subjectfiber-reinforced polymer (FRP)en
dc.subjectfiberglassen
dc.titleField and Laboratory Tests of a Proposed Bridge Deck Panel Fabricated from Pultruded Fiber-Reinforced Polymer Componentsen
dc.typeThesisen
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis.pdf
Size:
1.73 MB
Format:
Adobe Portable Document Format

Collections