Exhaust gas emissions from a prototype scrap tire incinerator/wastewater treatment plant sludge dryer

dc.contributor.authorTober, M. Lynen
dc.contributor.committeechairHughes, John M.en
dc.contributor.committeememberDietrich, Andrea M.en
dc.contributor.committeememberLittle, J.C.en
dc.contributor.departmentEnvironmental Sciences and Engineeringen
dc.date.accessioned2014-03-14T21:43:59Zen
dc.date.adate2008-08-29en
dc.date.available2014-03-14T21:43:59Zen
dc.date.issued1996en
dc.date.rdate2008-08-29en
dc.date.sdate2008-08-29en
dc.description.abstractIn conjunction with Atlantic Pacific Engineering and the Henry County Public Service Authority, Virginia Tech’s Environmental Engineering program measured the emissions from an experimental scrap tire incinerator/wastewater treatment plant sludge dryer. This report recounts the techniques used and the results obtained during this testing. The Virginia Department of Environmental Quality supplied a list of pollutants of permitting interest which included a variety of criteria pollutants, toxics, and metals. Sampling for all the listed compounds required adherence to EPA Methods 5, 201A, 29, 0010, 0011, 0030, 6, 7D, 26A, and 18. Emissions testing transpired during the incinerator’s 72-hour test burn: 0800 October 30th to 0800 November 2nd, 1995. Due to time constraints, only part of one nonpotable water sampling series was completed rather than the proposed duplicate testing using both drying agents: nonpotable water and sludge. High particulate (57 lb/hr) and metal (21.4 lb/hr total) emissions indicate a fairly significant amount of air pollution control equipment will be necessary for a commercial plant. Both nitrogen oxides and sulfur dioxide had low emission rates: 1.73 lb/hr and 0.64 lb/hr, respectively, due to the nonpotable water spray acting as a fairly efficient scrubber removing a great deal of nitrogen oxides, sulfur dioxide, and some metals. Because of sample analysis preparation problems, no organics results were obtained. Commercial development of this incinerator will have to include a sizable quantity of air pollution control equipment: a $5 million plant will need approximately $1 million worth of control equipment.en
dc.description.degreeMaster of Scienceen
dc.format.extentxi, 173 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-08292008-063306en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-08292008-063306/en
dc.identifier.urihttp://hdl.handle.net/10919/44484en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1996.T634.pdfen
dc.relation.isformatofOCLC# 35089118en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectscrap tiresen
dc.subjectcombustionen
dc.subjectemissionsen
dc.subjectsamplingen
dc.subjectrecyclingen
dc.subject.lccLD5655.V855 1996.T634en
dc.titleExhaust gas emissions from a prototype scrap tire incinerator/wastewater treatment plant sludge dryeren
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineEnvironmental Sciences and Engineeringen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V855_1996.T634.pdf
Size:
7.81 MB
Format:
Adobe Portable Document Format
Description:

Collections