Dynamic contrast sensitivity: methods and measurements

dc.contributor.authorOlesko, Brian M.en
dc.contributor.departmentPsychologyen
dc.date.accessioned2014-03-14T21:44:32Zen
dc.date.adate2009-09-05en
dc.date.available2014-03-14T21:44:32Zen
dc.date.issued1992en
dc.date.rdate2009-09-05en
dc.date.sdate2009-09-05en
dc.description.abstractA portable device was constructed which presents moving, computer generated, sine-wave grating slide projections that range in spatial frequency from 0.4 to 20.5 cycles per degree. At each of two different testing sessions, the contrast sensitivities of 60 undergraduate psychology majors were measured at a static, 25 deg/sec, and 50 deg/sec target movement condition. The results indicate that as target velocity was increased, contrast sensitivity decreased at middle and high spatial frequencies but that contrast sensitivity was enhanced at very low spatial frequencies by target movement. Also, the area of peak sensitivity shifted toward lower spatial frequencies as target velocity increased. In addition, test, re-test reliability was demonstrated. The results are consistent with previous Dynamic Visual Acuity (DVA) research which has shown that the ability to resolve fine detail decreases as target velocities increase, presumedly due to limitations in eye movement control. The testing device, which was designed and constructed for the present study, has proven to be a reliable means for measuring dynamic contrast sensitivity (DCS) and has some distinct advantages over existing methods for measuring both DVA and DCS and, as such, will be valuable in future DVA and DCS research.en
dc.description.degreeMaster of Scienceen
dc.format.extentvii, 54 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-09052009-040416en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-09052009-040416/en
dc.identifier.urihttp://hdl.handle.net/10919/44551en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1992.O447.pdfen
dc.relation.isformatofOCLC# 26615241en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1992.O447en
dc.subject.lcshContrast sensitivity (Vision)en
dc.subject.lcshVisual acuityen
dc.titleDynamic contrast sensitivity: methods and measurementsen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplinePsychologyen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V855_1992.O447.pdf
Size:
2.67 MB
Format:
Adobe Portable Document Format
Description:

Collections