Reliability of a semi-automated CO₂ rebreathing system for cardiac output measures during exercise

dc.contributor.authorDavis, Richard Alanen
dc.contributor.committeechairHerbert, William G.en
dc.contributor.committeememberDavis, Shala E.en
dc.contributor.committeememberSebolt, Don R.en
dc.contributor.departmentHealth and Physical Educationen
dc.date.accessioned2014-03-14T21:50:05Zen
dc.date.adate2008-11-18en
dc.date.available2014-03-14T21:50:05Zen
dc.date.issued1996-04-05en
dc.date.rdate2008-11-18en
dc.date.sdate2008-11-18en
dc.description.abstractComputer-assisted technology for noninvasive determination of cardiac output (Q̇, Lmin⁻¹) offers potential to re-examine measurement stability with established methods involving CO₂ rebreathing. Reproducibility of Q̇ was examined at rest and during steady-state cycle ergometer exercise (x̄ = 51% of V̇O₂pk; SD = ± 7%) using Defares’ exponential method (MedGraphics™ CPX/D system). Characteristics of the 19 female subjects were: (Mean and SD) age = 34.6 yr and 6.6 and V̇O₂pk= 32.8 mlkg⁻¹min⁻¹ and 9.5. The Q̇ trial consisted of 15 min of seated rest and 15 min of exercise. Values were determined in triplicate at each of minutes, 6, 10, 14. Stability of subjects responses before each rebreathing maneuver was verified by inspection of V̇O₂, Two-way ANOVA’s were performed on the Q̇ data for differences; means (Lmin⁻¹), SD’s, and reliability coefficients were: Rest Q̇-6 min Q̇-10 min Q̇-14 min R Day 1 5.1 ± 0.8 5.0 ± 1.1 4.8 ± 0.9 0.81 Day 2 4.7 ± 0.8 4.6 ± 0.8 4.6 ± 0.8 0.82 Exercise Q̇-6 min Q̇-10 min Q̇-14 min R Day 1 9.14 ± 1.2 9.3 ± 1.4 9.2 ± 1.1 0.93 Day 2 8.6 ± 1.5 8.7 ± 1.4 8.7 ± 1.3 0.97 Day 1 Day 2 R Rest 5.0 ± 0.8 4.7 ± 0.7 0.05 Exercise 9.2 ± 1.2 8.7 ± 1.4 0.84 Although these findings demonstrated within-test and between-test reproducibility of Q̇ to be comparable to that described in the published literature (Kirby TE. J Cardiac Rehabil 5:97-101, 1985) the new semi-automated computerized system (MedGraphics CPX/D) offers a quick, easy, and efficient assessment of cardiac output.en
dc.description.degreeMaster of Scienceen
dc.format.extentvii, 128 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-11182008-063156en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-11182008-063156/en
dc.identifier.urihttp://hdl.handle.net/10919/45843en
dc.language.isoenen
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1996.D385.pdfen
dc.relation.isformatofOCLC# 34929147en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subjectDefaresen
dc.subjectCardiac Outputen
dc.subjectCO₂ Rebreathingen
dc.subjectReliabilityen
dc.subject.lccLD5655.V855 1996.D385en
dc.titleReliability of a semi-automated CO₂ rebreathing system for cardiac output measures during exerciseen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineHealth and Physical Educationen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LD5655.V855_1996.D385.pdf
Size:
4.36 MB
Format:
Adobe Portable Document Format
Description:

Collections