The design, construction, and calibration of a generating voltmeter for a two million volt electrostatic accelerator
Files
TR Number
Date
1958
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Virginia Polytechnic Institute
Abstract
A generating voltmeter capable of measuring one, two, or found million volts has been designed and constructed for use with the Virginia Polytechnical Institute electrostatic accelerator. The voltmeter is a grounded shutter type, the rectified output of which is measured by a vacuum tube voltmeter. The voltmeter was calibrated by known nuclear resonances of fluoride. The calibration showed the meter to be accurate to within five percent at half scale deflation on the one million volts range the less than plus or minus three percent on the two million volts range.