Comparison of packed and wide-bore, open-tubular gas chromatographic columns

dc.contributor.authorShagena, Elizabeth C.en
dc.contributor.committeechairMcNair, Harold M.en
dc.contributor.committeememberBell, Harold M.en
dc.contributor.committeememberLong, Gary L.en
dc.contributor.committeememberHinshaw, J. V., Jr.en
dc.contributor.departmentChemistryen
dc.date.accessioned2014-03-14T21:50:18Zen
dc.date.adate2012-11-20en
dc.date.available2014-03-14T21:50:18Zen
dc.date.issued1987-05-15en
dc.date.rdate2012-11-20en
dc.date.sdate2012-11-20en
dc.description.abstractWide-bore, fused-silica capillary columns can be an excellent replacement for packed columns in many cases. They can provide higher surface inertness and thermal stability, as well as higher efficiency or speed of analysis. Wide-bore, open-tubular (WBOT) columns with thick films have higher sample capacities than conventional narrow-bore capillary columns and can be used in unmodified packed-column gas chromatographs. The majority of gas chromatographic analyses are still performed using packed columns. Many chromatographers associate open-tubular columns exclusively with split injection, often perceived as less repeatable or quantitative. Also, many packed-column methods use application-specific stationary phases which are not readily available on capillary columns. WBOT columns with standard phases can often be substituted due to higher available efficiencies. While several studies have been published on qualitative differences, there is little comparative quantitative data available on O.53รข mm I.D. and packed columns.en
dc.description.degreeMaster of Scienceen
dc.format.extentv, 105 leavesen
dc.format.mediumBTDen
dc.format.mimetypeapplication/pdfen
dc.identifier.otheretd-11202012-040115en
dc.identifier.sourceurlhttp://scholar.lib.vt.edu/theses/available/etd-11202012-040115/en
dc.identifier.urihttp://hdl.handle.net/10919/45896en
dc.publisherVirginia Techen
dc.relation.haspartLD5655.V855_1987.S523.pdfen
dc.relation.isformatofOCLC# 16837296en
dc.rightsIn Copyrighten
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en
dc.subject.lccLD5655.V855 1987.S523en
dc.subject.lcshColumnsen
dc.subject.lcshGas chromatographyen
dc.titleComparison of packed and wide-bore, open-tubular gas chromatographic columnsen
dc.typeThesisen
dc.type.dcmitypeTexten
thesis.degree.disciplineChemistryen
thesis.degree.grantorVirginia Polytechnic Institute and State Universityen
thesis.degree.levelmastersen
thesis.degree.nameMaster of Scienceen