    Abstract
    Three end-plate moment connection configurations are prequalified for special moment frames for seismic applications in AISC 358-10. The eight bolt extended stiffened connection is the strongest of the three configurations, but it can only develop approximately 30 percent of currently available hot-rolled beam sections. The strength of this configuration is limited by bolt strength. There is a need for a stronger end-plate moment connection, hence the reason for the development and validation of a twelve bolt configuration. Equations were developed for the design procedure using various analytical methods, which included yield line analysis and an effective tee stub model. An experimental program was conducted, which consisted of the full-scale cyclic testing of four end-plate moment connections. The intention of the testing was to develop and validate the design procedure, and prequalify a new twelve bolt configuration. A displacement-controlled loading protocol was applied according to AISC 341-10. The experimental results showed that the model for thick end-plate behavior is conservative by 6.7%, the model for end-plate yielding is conservative by 8.8%, and the model for bolt tension rupture with prying conservatively predicts by 18.5%. The specimens that were designed to form a plastic hinge in the beam fractured in a brittle manner. The deep beam specimen fractured in the first 2% story drift cycle, and the shallow beam specimen fractured in the second 3% story drift cycle. The fracture of the prequalification specimens was determined to have been caused by stiffeners of high yield stress relative to the beam yield stress.
    URI
    http://hdl.handle.net/10919/78230
    Collections
    • Masters Theses [19644]

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us
     

     

    VTechWorks

    AboutPoliciesHelp

    Browse

    All of VTechWorksCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Log inRegister

    Statistics

    View Usage Statistics

    If you believe that any material in VTechWorks should be removed, please see our policy and procedure for Requesting that Material be Amended or Removed. All takedown requests will be promptly acknowledged and investigated.

    Virginia Tech | University Libraries | Contact Us